BAK N21700-45D 4500mah - 60A

Reviews: Be the first to review this product

Additional Information

EAN / GTIN  6097316721730
Weight - g  69
Brand  BAK
Model   INR2170-45D
Size  21700
Battery chemistry  Li-ion
Voltage  3.6V
Min. capacity - mAh 4,400.00
Typ. capacity - mAh 4,500.00
Battery version  Flat top
Discharge current - A 60.00
Circuit protection  Unprotected
Height - mm 70.50
Diameter - mm 21.30

Availability: In stock

€3.95 (€ 3,26 without VAT)
  • Buy 10 times for €3.75 (€3.1 without VAT)   
  • Buy 100 times for €3.45 (€2.85 without VAT)   

* Required Fields

€3.95

Description

Details

Model: INR2170-45D

Capacity: 4400mAh
Typical capacity: 4500mAh
Rated Voltage 3.6 V
Max Discharge current 30A max.
Max Discharge current: 60A with 80C temperature cut off.
Plus pool: Flat top
Chemistry: Li-ion
Protection circuit: without
Cycle life (100% DOD 25°C): 600 cycles>60% (RT 8A / 30 a)
Operating temperature range( cell surface): charge: 0~55℃
Discharge: -20 ~ 80℃
Diameter: 21.30±0.15 mm
Height: 70.50±0.25 mm
Weight: 69g

Additional Information

Details

.

Reviews

Write Your Own Review

You're reviewing: BAK N21700-45D 4500mah - 60A

How do you rate this product? *

  1 star 2 stars 3 stars 4 stars 5 stars
Rating

Take care

  • Li-ion batteries can be dangerous when used wrong, short circuit or wrong usage can lead to fire or an explosion
  • Do not put the battery in a charger or equipment with wrong terminals connected
  • Never short cut the battery. Take care you don’t short cut it accidentally, do not put it in your pocked together with bunch of keys
  • Do not disassemble or deform the battery. Dispose it if the battery is deformed
  • Do not immerse in water
  • Avoid excessive physical shock or vibration
  • Do not expose to, dispose of the battery in fire
  • Keep out of the reach of children
  • Never use a modified or damaged charger
  • Do not leave battery in charger over 12 hours
  • Store the battery in a cool, dry and well-ventilated area
  • Dispose of in accordance with local regulations
  • Do not solder on these cells